• Cat7 Ethernet Bulk Cable, 1000ft (305m), 23AWG
  • Cat7 Ethernet Bulk Cable, 1000ft (305m), 23AWG

Cat7 Ethernet Bulk Cable, 1000ft (305m), 23AWG

Cat7 Ethernet Bulk Cable, 1000ft (305m), 23AWG Solid Pure Bare Copper Wire, 1000MHz, Shielded (S/FTP), PVC CMR, with Reel (Blue)

● Product origin: China

● Delivery time: 7 -10 workdays

We are manufacturer that could support you good quality with aggressive price. Believe that we are the best choice for you from many traders and resellers.

Accepted OEM/ ODM

Welcome to send us any of your questions and inquiries, we are more than pleasure to send you more information.

  • Cat7 Ethernet Bulk Cable, 1000ft (305m), 23AWG

Description

Cat7 Ethernet Bulk Cable, 1000ft (305m), 23AWG Solid Pure Bare Copper Wire, 1000MHz, Shielded (S/FTP), PVC CMR, with Reel (Blue)

Key attributes

Cat7 has been designed as a standard for 10 Gigabit Ethernet over 100m of copper cabling. It has a higher bandwidth of up to 1000MHz and backwards compatible with traditional Cat5e, Cat6 and Cat6a Ethernet. This cable offers extensive shielding to reduce signal attenuation and is relatively stiff in comparison to previous generations of cabling. It is great for datacenters, server rooms, and telecommunications rooms.

Description

Specification

Cable Type Category 7 Shielding Type S/FTP
Cable jacket PVC CMR Cable Length 1000ft(305m)
Reference Bandwidth 1000MHz Data Rate Support 1G/10GBase-T
Wire Gauge 23AWG Conductor Type Pure Bare Copper Wire
Putup Type Reel Cable Outer Diameter (mm) 7.6 ± 0.50
Conductor Diameter (mm) 0.560±0.005 Bend Radius (mm)
32.4
Maximum installation Tension
(N)
110 Standard ISO/IEC 11801
Operating Temperature -20 to 75°C (-4 to 167°F) Installation Temperature -10 to 50°C (-14 to 122°F)

Features and Benefits

  1. CMR Rated (Riser) for Use in Between Floors, In-Wall, And Non-plenum Spaces
  2. Less Susceptible to RFI/EMI in Noisy Environments
  3. Up to 1000MHz with 1G/10G-T Speed, Support PoE/PoE+/PoE++ (IEEE 802.3af/at/bt)
  4. Tested with a Fluke DSX-8000 Versiv Cable Analyzer
  5. Fully Compliant with UL® Fire and Safety Standards
  6. Support Solution Testing and Validation, And Can Provide Demo Testing
  7. Marked Every 1m (3.28ft) on Cable Makes Measuring Easy
  8. Multiple Colors&Lengths to Help Organize and Simplify Complicated Cable Runs

FAQ

Q1: Can Cat6a cables be bent during installation?
A1: Yes, but excessive bending or pulling may damage internal conductors.
It’s recommended to follow the minimum bend radius and avoid excessive force during installation.

Q2: Can I terminate Cat6a cable with Cat6 connectors?
A2: 
Technically yes, but not recommended. Using non-Cat6a connectors may: Reduce performance & Increase failure risk over time.

Q3: Is shielding necessary for industrial Ethernet cables?
A3: Yes, shielding is critical in industrial environments to reduce EMI/RFI interference and ensure stable transmission.

Q4: Do shielded cables need grounding?
A4:
In most industrial setups, grounding is recommended for optimal shielding performance, while improper grounding may reduce its effectiveness.

Q5: Is bulk cable better than pre-made patch cables?
A5: Yes for large projects: More cost-effective,Custom length flexibility,Suitable for structured cabling