Cat5e Ethernet Bulk Cable, 1000ft (305m), 24AWG Solid Pure Bare Copper Wire, 350MHz, Unshielded (UTP), PVC CMR, with Reel (Blue)
Maximize network performance and ensure unwavering stability for legacy IP systems, network upgrades, and cost-conscious projects with SkywardCable's Category 5e cables. Engineered to exceed TIA-568-C.2 standards, our cables deliver superior performance.
● Product origin: China
● Delivery time: 7 -10 workdays
We are manufacturer that could support you good quality with aggressive price. Believe that we are the best choice for you from many traders and resellers.
Accepted OEM/ ODM
Welcome to send us any of your questions and inquiries, we are more than pleasure to send you more information.
Cat5e cable is a "twisted pair" network cable used for 1000Base-T Ethernet applications at speed of up to 350MHz of bandwidth. This cable is preferred for more advanced networking installations where a higher bandwidth than normal is required. You can install it for your devices at home, in offices, hotels, and surveillance system for stable network connection.
| Cable Type | Category 5e | Shielding Type | UTP |
| Cable jacket | PVC CMR | Cable Length | 1000ft (305m) |
| Reference Bandwidth | 350MHz | Data Rate Support | 10/100/1000Base-T |
| Wire Gauge | 24AWG | Conductor Type | Pure Bare Copper Wire |
| Putup Type | Reel | Number of Conductors | 4 Pairs |
| Conductor Diameter (mm) | 0.500 ± 0.005 | Cable Outer Diameter (mm | 5.00 ± 0.40 |
| Maximum Installation Tension (N) | 110 | Bend Radius (mm) | 21.6 |
| Cable Color | Blue | Standard | ISO/IEC 11801, ANSI/TIA-568.2-D |
| Operating Temperature | -20 to 75°C (-4 to 167°F) | Installation Temperature | -10 to 50°C (-14 to 122°F) |
Q1: Can Cat6a cables be bent during installation?
A1: Yes, but excessive bending or pulling may damage internal conductors.
It’s recommended to follow the minimum bend radius and avoid excessive force during installation.
Q2: Can I terminate Cat6a cable with Cat6 connectors?
A2: Technically yes, but not recommended. Using non-Cat6a connectors may: Reduce performance & Increase failure risk over time.
Q3: Is shielding necessary for industrial Ethernet cables?
A3: Yes, shielding is critical in industrial environments to reduce EMI/RFI interference and ensure stable transmission.
Q4: Do shielded cables need grounding?
A4: In most industrial setups, grounding is recommended for optimal shielding performance, while improper grounding may reduce its effectiveness.
Q5: Is bulk cable better than pre-made patch cables?
A5: Yes for large projects: More cost-effective,Custom length flexibility,Suitable for structured cabling